Rack air distribution unit 2u 208 230v 50 60hz.
Apc rack air containment system.
The hot aisle containment system can be built using new american power conversion apc equipment or with existing apc.
The containment system is designed to create a separate environment for air distribution in order to prevent mixing of hot and cold air streams.
The hot aisle containment system encloses a hot aisle to collect and cool equipment exhaust making it available for cool air intakes.
The rack air containment system racs is a modular front and rear plenum for use in isolating the supply and return air between an apc netshelter sx rack enclosure and an apc inrow cooling solution.
Mixing of hot and cold air streams in the data center lowers availability of it equipment.
By containing the hot aisle the hot and cold air streams are separated.
The modular design and ability to retrofit to an existing netshelter sx rack enables medium to high density racks to be cooled in an autonomous.
Apc application note 90 rack air containment application guidelines and approved configurations by kevin dunlapabstractthe rack air containment system racs is a modular front and rear plenum for use in isolating the supply and return airbetween an apc netshelter sx rack enclosure and an apc inrow cooling unit.
The apc rack air distribution unit is a 2u fan unit that works with an existing precision air conditioning system to deliver cool air to the equipment contained in a rack enclosure.
The rack air containment system racs is a mechanical ducting system that attaches to the front or rear of an enclosure to provide increased cooling capacity.
Apc inrack racs configurations 1.
The containment system is designed to create a separate environment for air distribution in order to prevent mixing of hot and cold air streams resulting in a more predictable cooling pattern.
This prevents the conditioned.
The racs is a modular system that works with apc netshelter sx enclosures and inrow cooling units to provide maximum cooling predictability capacity and efficiency.
This creates a self contained system capable of supporting high density power loads.
The rack air distribution unit connects into the raised floor and pulls supply air directly into the enclosure.
A hot aisle containment system hacs encloses the hot aisle to collect the it equipment s hot exhaust air allowing the rest of the data center to become a large cold air return plenum.
The rack air distribution unit is a 2u fan unit that connects into the raised floor and pulls supply air directly into the enclosure.